<?xml version="1.0" encoding="UTF-8"?><!-- generator="wordpress/2.0.2" -->
<rss version="2.0" 
	xmlns:content="http://purl.org/rss/1.0/modules/content/">
<channel>
	<title>Comentarios en: MODBUS TCP para PIC (parte I)</title>
	<link>http://blog.sasian.es/2010/01/08/modbus-tcp-para-pic-parte-i/</link>
	<description>algunas cosas que he usado y que pueden ser útiles a otros....</description>
	<pubDate>Tue, 22 May 2012 09:17:20 +0000</pubDate>
	<generator>http://wordpress.org/?v=2.0.2</generator>

	<item>
		<title>Por: arthur.rush</title>
		<link>http://blog.sasian.es/2010/01/08/modbus-tcp-para-pic-parte-i/#comment-597</link>
		<pubDate>Thu, 26 Jan 2012 23:35:13 +0000</pubDate>
		<guid>http://blog.sasian.es/2010/01/08/modbus-tcp-para-pic-parte-i/#comment-597</guid>
					<description>I’m a newbie and not a C programmer, I have many years in programming Modicon PLC and in some PLCs in basic code.
But I need to interface some sensor that are I2C data bus so I need to use a controller with I2C bus.
I found a SBC65EC controller with a I2C bus I can use. I hopping to copy and pace Modbus RTU TCP/IP code into my SBC65EC source code.I copy and paced to Modbus TCP codes into my project, but received syntex errors 1099 and 270. Do you know how fix this errors?
I can send you me project if you wont it
arthur.rush@csus.edu</description>
		<content:encoded><![CDATA[<p>I’m a newbie and not a C programmer, I have many years in programming Modicon PLC and in some PLCs in basic code.<br />
But I need to interface some sensor that are I2C data bus so I need to use a controller with I2C bus.<br />
I found a SBC65EC controller with a I2C bus I can use. I hopping to copy and pace Modbus RTU TCP/IP code into my SBC65EC source code.I copy and paced to Modbus TCP codes into my project, but received syntex errors 1099 and 270. Do you know how fix this errors?<br />
I can send you me project if you wont it<br />
<a href="mailto:arthur.rush@csus.edu">arthur.rush@csus.edu</a>
</p>
]]></content:encoded>
				</item>
	<item>
		<title>Por: dariooirad</title>
		<link>http://blog.sasian.es/2010/01/08/modbus-tcp-para-pic-parte-i/#comment-520</link>
		<pubDate>Mon, 15 Aug 2011 00:28:58 +0000</pubDate>
		<guid>http://blog.sasian.es/2010/01/08/modbus-tcp-para-pic-parte-i/#comment-520</guid>
					<description>Hola Felix
Soy algo nuevo en esto y me gustaria mucho realizar este proyecto, ¿cual seria el hardware que tengo que implementar, diagramas electricos, pcb, etc? para empezar a probar.
Te felicito por el proyecto.
Te mando Saludos</description>
		<content:encoded><![CDATA[<p>Hola Felix<br />
Soy algo nuevo en esto y me gustaria mucho realizar este proyecto, ¿cual seria el hardware que tengo que implementar, diagramas electricos, pcb, etc? para empezar a probar.<br />
Te felicito por el proyecto.<br />
Te mando Saludos
</p>
]]></content:encoded>
				</item>
	<item>
		<title>Por: felix</title>
		<link>http://blog.sasian.es/2010/01/08/modbus-tcp-para-pic-parte-i/#comment-519</link>
		<pubDate>Mon, 08 Aug 2011 19:20:11 +0000</pubDate>
		<guid>http://blog.sasian.es/2010/01/08/modbus-tcp-para-pic-parte-i/#comment-519</guid>
					<description>Hola jceduvi,
hay sutiles diferencias entre el código para modbus tcp y el necesario para rs485. Afortunadamente creo recordar que, por ejemplo CCS tiene la librería completa que necesitas para RS485.
un saludo</description>
		<content:encoded><![CDATA[<p>Hola jceduvi,<br />
hay sutiles diferencias entre el código para modbus tcp y el necesario para rs485. Afortunadamente creo recordar que, por ejemplo CCS tiene la librería completa que necesitas para RS485.<br />
un saludo
</p>
]]></content:encoded>
				</item>
	<item>
		<title>Por: felix</title>
		<link>http://blog.sasian.es/2010/01/08/modbus-tcp-para-pic-parte-i/#comment-518</link>
		<pubDate>Mon, 08 Aug 2011 19:18:15 +0000</pubDate>
		<guid>http://blog.sasian.es/2010/01/08/modbus-tcp-para-pic-parte-i/#comment-518</guid>
					<description>Hi Songotag,
no new versions, I've some pics conected to my Kepware OPC and some others conected to a magelis XBTG5330 for more than 1 year.
do you have some problem running the code?
felix</description>
		<content:encoded><![CDATA[<p>Hi Songotag,<br />
no new versions, I&#8217;ve some pics conected to my Kepware OPC and some others conected to a magelis XBTG5330 for more than 1 year.<br />
do you have some problem running the code?<br />
felix
</p>
]]></content:encoded>
				</item>
	<item>
		<title>Por: jceduvi</title>
		<link>http://blog.sasian.es/2010/01/08/modbus-tcp-para-pic-parte-i/#comment-517</link>
		<pubDate>Mon, 08 Aug 2011 17:21:03 +0000</pubDate>
		<guid>http://blog.sasian.es/2010/01/08/modbus-tcp-para-pic-parte-i/#comment-517</guid>
					<description>Saludos, ando realizando mi proyecto de tesis en el cual quiero utilizar una comunicación a travez de un microcontrolador con un controlador de la marca delta,
 alguien me podría ayudar a orientarme un poco eso pues el controlador se comunica por 485 con modbus, a mas estoy utilizando para esto el mikroc para programar el pic, no se si alguien me podria dar una ayuda al respecto.</description>
		<content:encoded><![CDATA[<p>Saludos, ando realizando mi proyecto de tesis en el cual quiero utilizar una comunicación a travez de un microcontrolador con un controlador de la marca delta,<br />
 alguien me podría ayudar a orientarme un poco eso pues el controlador se comunica por 485 con modbus, a mas estoy utilizando para esto el mikroc para programar el pic, no se si alguien me podria dar una ayuda al respecto.
</p>
]]></content:encoded>
				</item>
	<item>
		<title>Por: songotag</title>
		<link>http://blog.sasian.es/2010/01/08/modbus-tcp-para-pic-parte-i/#comment-509</link>
		<pubDate>Mon, 13 Jun 2011 18:02:20 +0000</pubDate>
		<guid>http://blog.sasian.es/2010/01/08/modbus-tcp-para-pic-parte-i/#comment-509</guid>
					<description>Hola Felix

Did you done another version of code for the Modbus ?

I whant to use a sbc65ec and a magelis from telemecanique

thanks for your help</description>
		<content:encoded><![CDATA[<p>Hola Felix</p>
<p>Did you done another version of code for the Modbus ?</p>
<p>I whant to use a sbc65ec and a magelis from telemecanique</p>
<p>thanks for your help
</p>
]]></content:encoded>
				</item>
	<item>
		<title>Por: songotag</title>
		<link>http://blog.sasian.es/2010/01/08/modbus-tcp-para-pic-parte-i/#comment-508</link>
		<pubDate>Mon, 13 Jun 2011 10:07:04 +0000</pubDate>
		<guid>http://blog.sasian.es/2010/01/08/modbus-tcp-para-pic-parte-i/#comment-508</guid>
					<description>Hello Felix, did you make some adjustement to the code ? I whant to use it with a sbc68ec...

thanks for your help</description>
		<content:encoded><![CDATA[<p>Hello Felix, did you make some adjustement to the code ? I whant to use it with a sbc68ec&#8230;</p>
<p>thanks for your help
</p>
]]></content:encoded>
				</item>
	<item>
		<title>Por: Donde Publicar Articulos</title>
		<link>http://blog.sasian.es/2010/01/08/modbus-tcp-para-pic-parte-i/#comment-505</link>
		<pubDate>Sat, 29 Jan 2011 12:03:27 +0000</pubDate>
		<guid>http://blog.sasian.es/2010/01/08/modbus-tcp-para-pic-parte-i/#comment-505</guid>
					<description>&lt;strong&gt;Me gustaria leer su blog....&lt;/strong&gt;

Está haciendo un trabajo genial....</description>
		<content:encoded><![CDATA[<p><strong>Me gustaria leer su blog&#8230;.</strong></p>
<p>Está haciendo un trabajo genial&#8230;.
</p>
]]></content:encoded>
				</item>
	<item>
		<title>Por: expo3871</title>
		<link>http://blog.sasian.es/2010/01/08/modbus-tcp-para-pic-parte-i/#comment-501</link>
		<pubDate>Sat, 16 Oct 2010 02:26:34 +0000</pubDate>
		<guid>http://blog.sasian.es/2010/01/08/modbus-tcp-para-pic-parte-i/#comment-501</guid>
					<description>Hola felix he estado analizando detenidamente la trama de la explorer 16 y compara con las tramas generadas entre la comunicacion de 2 plcs quantum y note lo siguiente: Al final de cada respuesta se esta enviando un oxFF que no se deberia estar enviando, por lo tanto comente esta linea que envia el 0xFF pero me da un error con la longitud, ya que al parecer para el calculo de la longitud del paquete se esta tomanto en cuenta ese byte, entonces me da un error porque el length tiene un valor mas del que deberia ser, entonces el PLC cuando ve q la trama deberia de ser de x longitud y le llega x-1 pues lo ve como un error y la descarta. Necesito tu ayuda para acomodar para que el calculo del length no tome en cuenta este ultimo byte de 0xFF ya que esta de mas. Gracias de antemano.

Saludos.</description>
		<content:encoded><![CDATA[<p>Hola felix he estado analizando detenidamente la trama de la explorer 16 y compara con las tramas generadas entre la comunicacion de 2 plcs quantum y note lo siguiente: Al final de cada respuesta se esta enviando un oxFF que no se deberia estar enviando, por lo tanto comente esta linea que envia el 0xFF pero me da un error con la longitud, ya que al parecer para el calculo de la longitud del paquete se esta tomanto en cuenta ese byte, entonces me da un error porque el length tiene un valor mas del que deberia ser, entonces el PLC cuando ve q la trama deberia de ser de x longitud y le llega x-1 pues lo ve como un error y la descarta. Necesito tu ayuda para acomodar para que el calculo del length no tome en cuenta este ultimo byte de 0xFF ya que esta de mas. Gracias de antemano.</p>
<p>Saludos.
</p>
]]></content:encoded>
				</item>
	<item>
		<title>Por: expo3871</title>
		<link>http://blog.sasian.es/2010/01/08/modbus-tcp-para-pic-parte-i/#comment-499</link>
		<pubDate>Sat, 16 Oct 2010 02:16:36 +0000</pubDate>
		<guid>http://blog.sasian.es/2010/01/08/modbus-tcp-para-pic-parte-i/#comment-499</guid>
					<description>Hola felix, he estado analizando detenidamente la trama y compare con las tramas generadas por la comunicacion con 2 plc quatum y note lo siguiente:
Al final se esta enviando un 0xFF que no se deberia estar enviando, por lo tanto comente esa linea que envia el 0xFF pero me da un error con la longitud, ya que al parecer en el calculo de la longitud del paquete se esta contando ese byte, entonces me da un error porque el lenght tiene un valor mas del que deberia de ser, entonces el plc al ver que esta esperando x paquetes y le llegan x-1 pues descarta el mensaje. Donde necesito tu ayuda es para ver donde puedo acomodar para que el calculo del lenght no me tome en cuenta ese byte de 0xFF ya que esta demas. 
Saludos</description>
		<content:encoded><![CDATA[<p>Hola felix, he estado analizando detenidamente la trama y compare con las tramas generadas por la comunicacion con 2 plc quatum y note lo siguiente:<br />
Al final se esta enviando un 0xFF que no se deberia estar enviando, por lo tanto comente esa linea que envia el 0xFF pero me da un error con la longitud, ya que al parecer en el calculo de la longitud del paquete se esta contando ese byte, entonces me da un error porque el lenght tiene un valor mas del que deberia de ser, entonces el plc al ver que esta esperando x paquetes y le llegan x-1 pues descarta el mensaje. Donde necesito tu ayuda es para ver donde puedo acomodar para que el calculo del lenght no me tome en cuenta ese byte de 0xFF ya que esta demas.<br />
Saludos
</p>
]]></content:encoded>
				</item>
</channel>
</rss>